516 research outputs found
Should adjustment for covariates be used in prevalence estimations?
Background
Adjustment for covariates (also called auxiliary variables in survey sampling literature) is commonly applied in health surveys to reduce the variances of the prevalence estimators. In theory, adjusted prevalence estimators are more accurate when variance components are known. In practice, variance components needed to achieve the adjustment are unknown and their sample estimators are used instead. The uncertainty introduced by estimating variance components may overshadow the reduction in the variance of the prevalence estimators due to adjustment. We present empirical guidelines indicating when adjusted prevalence estimators should be considered, using gender adjusted and unadjusted smoking prevalence as an illustration. Methods
We compare the accuracy of adjusted and unadjusted prevalence estimators via simulation. We simulate simple random samples from hypothetical populations with the proportion of males ranging from 30% to 70%, the smoking prevalence ranging from 15% to 35%, and the ratio of male to female smoking prevalence ranging from 1 to 4. The ranges of gender proportions and smoking prevalences reflect the conditions in 1999–2003 Behavioral Risk Factors Surveillance System (BRFSS) data for Massachusetts. From each population, 10,000 samples are selected and the ratios of the variance of the adjusted prevalence estimators to the variance of the unadjusted (crude) ones are computed and plotted against the proportion of males by population prevalence, as well as by population and sample sizes. The prevalence ratio thresholds, above which adjusted prevalence estimators have smaller variances, are determined graphically. Results
In many practical settings, gender adjustment results in less accuracy. Whether or not there is better accuracy with adjustment depends on sample sizes, gender proportions and ratios between male and female prevalences. In populations with equal number of males and females and smoking prevalence of 20%, the adjusted prevalence estimators are more accurate when the ratios of male to female prevalences are above 2.4, 1.8, 1.6, 1.4 and 1.3 for sample sizes of 25, 50, 100, 150 and 200, respectively. Conclusion
Adjustment for covariates will not result in more accurate prevalence estimator when ratio of male to female prevalences is close to one, sample size is small and risk factor prevalence is low. For example, when reporting smoking prevalence based on simple random sampling, gender adjustment is recommended only when sample size is greater than 200
Higher-order multipole amplitudes in charmonium radiative transitions
Using 24 million decays in CLEO-c, we have searched
for higher multipole admixtures in electric-dipole-dominated radiative
transitions in charmonia. We find good agreement between our data and
theoretical predictions for magnetic quadrupole (M2) amplitudes in the
transitions and ,
in striking contrast to some previous measurements. Let and
denote the normalized M2 amplitudes in the respective aforementioned decays,
where the superscript refers to the angular momentum of the . By
performing unbinned maximum likelihood fits to full five-parameter angular
distributions, we determine the ratios and , where
the theoretical predictions are independent of the charmed quark magnetic
moment and are and .Comment: 32 pages, 7 figures, acceptance updat
Dalitz Plot Analysis of Ds to K+K-pi+
We perform a Dalitz plot analysis of the decay Ds to K+K-pi+ with the CLEO-c
data set of 586/pb of e+e- collisions accumulated at sqrt(s) = 4.17 GeV. This
corresponds to about 0.57 million D_s+D_s(*)- pairs from which we select 14400
candidates with a background of roughly 15%. In contrast to previous
measurements we find good agreement with our data only by including an
additional f_0(1370)pi+ contribution. We measure the magnitude, phase, and fit
fraction of K*(892) K+, phi(1020)pi+, K0*(1430)K+, f_0(980)pi+, f_0(1710)pi+,
and f_0(1370)pi+ contributions and limit the possible contributions of other KK
and Kpi resonances that could appear in this decay.Comment: 21 Pages,available through http://www.lns.cornell.edu/public/CLNS/,
submitted to PR
Search for D0 to p e- and D0 to pbar e+
Using data recorded by CLEO-c detector at CESR, we search for simultaneous
baryon and lepton number violating decays of the D^0 meson, specifically, D^0
--> p-bar e^+, D^0-bar --> p-bar e^+, D^0 --> p e^- and D^0-bar --> p e^-. We
set the following branching fraction upper limits: D^0 --> p-bar e^+ (D^0-bar
--> p-bar e^+) p e^- (D^0-bar --> p e^-) < 1.2 *
10^{-5}, both at 90% confidence level.Comment: 10 pages, available through http://www.lns.cornell.edu/public/CLNS/,
submitted to PRD. Comments: changed abstract, added reference for section 1,
vertical axis in Fig.5 changed (starts from 1.5 rather than 2.0), fixed typo
Charmonium decays to gamma pi0, gamma eta, and gamma eta'
Using data acquired with the CLEO-c detector at the CESR e+e- collider, we
measure branching fractions for J/psi, psi(2S), and psi(3770) decays to gamma
pi0, gamma eta, and gamma eta'. Defining R_n = B[ psi(nS)-->gamma eta ]/B[
psi(nS)-->gamma eta' ], we obtain R_1 = (21.1 +- 0.9)% and, unexpectedly, an
order of magnitude smaller limit, R_2 < 1.8% at 90% C.L. We also use
J/psi-->gamma eta' events to determine branching fractions of improved
precision for the five most copious eta' decay modes.Comment: 14 pages, available through http://www.lns.cornell.edu/public/CLNS/,
published in Physical Review
Precision Measurement of B(D+ -> mu+ nu) and the Pseudoscalar Decay Constant fD+
We measure the branching ratio of the purely leptonic decay of the D+ meson
with unprecedented precision as B(D+ -> mu+ nu) = (3.82 +/- 0.32 +/-
0.09)x10^(-4), using 818/pb of data taken on the psi(3770) resonance with the
CLEO-c detector at the CESR collider. We use this determination to derive a
value for the pseudoscalar decay constant fD+, combining with measurements of
the D+ lifetime and assuming |Vcd| = |Vus|. We find fD+ = (205.8 +/- 8.5 +/-
2.5) MeV. The decay rate asymmetry [B(D+ -> mu+ nu)-B(D- -> mu- nu)]/[B(D+ ->
mu+ nu)+B(D- -> mu- nu)] = 0.08 +/- 0.08, consistent with no CP violation. We
also set 90% confidence level upper limits on B(D+ -> tau+ nu) < 1.2x10^(-3)
and B(D+ -> e+ nu) < 8.8x10^(-6).Comment: 24 pages, 11 figures and 6 tables, v2 replaced some figure vertical
axis scales, v3 corrections from PRD revie
Precision Measurement of the Mass of the h_c(1P1) State of Charmonium
A precision measurement of the mass of the h_c(1P1) state of charmonium has
been made using a sample of 24.5 million psi(2S) events produced in e+e-
annihilation at CESR. The reaction used was psi(2S) -> pi0 h_c, pi0 -> gamma
gamma, h_c -> gamma eta_c, and the reaction products were detected in the
CLEO-c detector.
Data have been analyzed both for the inclusive reaction and for the exclusive
reactions in which eta_c decays are reconstructed in fifteen hadronic decay
channels. Consistent results are obtained in the two analyses. The averaged
results of the present measurements are M(h_c)=3525.28+-0.19 (stat)+-0.12(syst)
MeV, and B(psi(2S) -> pi0 h_c)xB(h_c -> gamma eta_c)= (4.19+-0.32+-0.45)x10^-4.
Using the 3PJ centroid mass, Delta M_hf(1P)= - M(h_c) =
+0.02+-0.19+-0.13 MeV.Comment: 9 pages, available through http://www.lns.cornell.edu/public/CLNS/,
submitted to PR
Measurement of the Absolute Branching Fraction of D_s^+ --> tau^+ nu_tau Decay
Using a sample of tagged D_s decays collected near the D^*_s D_s peak
production energy in e+e- collisions with the CLEO-c detector, we study the
leptonic decay D^+_s to tau^+ nu_tau via the decay channel tau^+ to e^+ nu_e
bar{nu}_tau. We measure B(D^+_s to tau^+ nu_tau) = (6.17 +- 0.71 +- 0.34) %,
where the first error is statistical and the second systematic. Combining this
result with our measurements of D^+_s to mu^+ nu_mu and D^+_s to tau^+ nu_tau
(via tau^+ to pi^+ bar{nu}_tau), we determine f_{D_s} = (274 +- 10 +- 5) MeV.Comment: 9 pages, postscript also available through
http://www.lns.cornell.edu/public/CLNS/2007/, revise
J/psi and psi(2S) Radiative Transitions to eta_c
Using 24.5 million psi(2S) decays collected with the CLEO-c detector at CESR
we present the most precise measurements of magnetic dipole transitions in the
charmonium system. We measure B(psi(2S)->gamma eta_c) =
(4.32+/-0.16+/-0.60)x10^-3, B(J/psi->gamma eta_c)/B(psi(2S)->gamma eta_c) =
4.59+/-0.23+/-0.64, and B(J/psi->gamma eta_c) = (1.98+/-0.09+/-0.30)%. We
observe a distortion in the eta_c line shape due to the photon-energy
dependence of the magnetic dipole transition rate. We find that measurements of
the eta_c mass are sensitive to the line shape, suggesting an explanation for
the discrepancy between measurements of the eta_c mass in radiative transitions
and other production mechanisms.Comment: 11 pages, 3 figure
- …